Downloads

Membership Has It's Rewards
Become an Aniara Member today and enjoy member-only promotional programs. No purchase is required to become an Aniara Member. Click here for membership terms and conditions, details on current promotional programs and to register for membership.
|
|
Calibrators & Controls
The range of calibrators and controls proposed allows standardizing the assays and validating the series.
They are established in accordance with International Standards from the National Institute for Biological Standards and Controls (NIBSC, Potters Bar, UK), when available.Calibrators and controls offer prolonged stability following reconstitution.
Calibrators and Controls for Clotting Assays
Heparin and Analogues
Non Titrated Human Plasmas (Normal)
Calibrators & Controls for Plasma Factors & Co-Factors
Lupus Anticoagulant (Plasma)
Direct Factor Xa Inhibitors (Rivaroxaban)
Controls for Enzyme Immuno-Assays
HYPHEN BioMed proposes various controls for peculiar hemostasis or Fibrinolysis proteins, or blood markers, which can be used with any enzyme Immuno-assay. Reactivity of the Immuno-assay used, and its calibration method, must be considered for adjusting the control value indicated, if required.
Calibrators and controls (two levels) are included in all the ELISA kits in the ZYMUTEST line. Separate control kits (two levels) are also included, which can be used in any Immuno-assay for the indicated parameter.
Controls for Enzyme Immuno-Assays
Controls for the ELITEST Line of Cardiovascular Assays
Heparin Kits and HIT Assays
ZYMUTEST HIA kits offer a range of immuno-assays designed for testing heparin dependent antibodies, involved in the development of Heparin Induced Thrombocytopenia (HIT) or Heparin Induced Thrombocytopenia and Thrombosis (HITT). ZYMUTEST HIA, IGAM (ARK040D) measures the total antibodies, offering the highest sensitivity as all isotypes are detected. It is the preferred assay when an early detection of heparin dependent antibodies is required for assessing the development risk of HIT/HITT. ZYMUTEST HIA, IgG (ARK040A) measures only the IgG isotype, which is reported as being the most associated with the clinical complications of heparin dependent antibodies (HIT/HITT), allowing confirmation of the diagnosis of HIT/HITT or its clinical suspicion. However, some cases associated with only IgM and/or IgA isotypes can be missed. ZYMUTEST HIA, IgG, IgM and IgA (ARK040E) is designed for the full isotyping of heparin dependent antibodies, applications to characterize isotype distribution in patients with a risk or a suspicion of HIT/HITT, or for research investigations.
Diagnosis of Heparin Induced Thrombocytopenia (HIT)
|
|
Videos
SKU # A223301 BIOPHEN Abnormal Control Plasma |
SKU # A224101 BIOPHEN UFH Control - C1 |
SKU # A221025 BIOPHEN Heparin Anti-IIa (2 Stages) |
SKU # A224701 Dabigatran (Pradaxa) Control Plasma |
SKU # A222001 BIOPHEN Heparin Calibrator |
SKU # A222801 Dabigatran (Pradaxa) Plasma Calibrator |
SKU # A223701 BIOPHEN LMWH Control Low |
SKU # ARK040A ZYMUTEST HIA IgG |
SKU # A224301 BIOPHEN LMWH Control Low Cl |
SKU # ARK040D ZYMUTEST HIA IgGAM |
SKU # A223001 BIOPHEN LMWH Control Plasma |
SKU # ARK041A ZYMUTEST HIA Mono Strip, IgG |
SKU # A222101 BIOPHEN Plasma Calibrator |
SKU # ARK041D ZYMUTEST HIA Mono strip, IgGAM |

These videos can be viewed with the Flash Plugin. |